3 - 10
Follower Scaling Parameters
The M-Traverse allows you to use Engineering Units (e.g., feet, inches) to control and
monitor your system. Follower Scaling is a convenient method for converting encoder
lines to Engineering Units. Scaling Control Parameters give the M-Traverse the
following information:
Engineering Units (CP-15)
In a level wind application, CP-15 is your Engineering Unit (E.U.)
measurement of a laypitch. In a web scanning application, CP-15 is
your E.U. measurement for a traverse length. If your application uses
the M-Traverse's setpoint flexibility to change over the operation, and
you have more than one measurement, then pick one arbitrarily.
However, be sure to reference that same measurement consistently
throughout the scaling set up. In setting up the scaling, you are simply
allowing the M-Traverse to establish a conversion of encoder lines to
the E.U. that you prefer to use. Place the decimal in the location of
your desired resolution (to the tens, hundreds or thousands place). All
of the other Control Parameters or Monitor Parameters that display in
E.U.s will automatically display the correct decimal position.
Lead PPR Reel (CP-16)
In a level wind application, CP-16 is the number of Lead encoder lines
that the Lead Frequency input registers as a result of one revolution of
the reel. In a web scanning application, CP-16 is the number of Lead
encoder lines that the Lead Frequency input registers when the
Follower travels one traverse length. When you calculate this variable,
be sure to consider all gear reductions, belt reductions and other types
of reducers. Use the following procedure to check CP-16:
• Place the M-Traverse in F-Stop.
Activate the Home Set input (clears the Lead position to zero).
• Place the M-Traverse in F-Stop.
• Display MV-43 (Lead Position).
• Move the Lead either one revolution of the reel (level wind) or one
traverse length (web scan).
• MV-43 should have the same value as CP-16.
Follower Lines per Engineering Units (CP-17)
In a level wind application, CP-17 is the number of Follower encoder
lines that the Feedback Frequency input registers as a result of the
Follower laypitch that was entered in CP-15. In a web scanning
application,