The factory defaults for the Output B Control Parameters are found in Table 3-34. To
modify the default parameters refer to Table 3-35. If you are uncertain how to enter a
Control Parameter, review the
Operations: Keypad
section.
Table 3-36 Default Control Parameters for Output B
CP Parameter Name Parameter Value
CP-93 Output B Segment 1
CP-94 Output B Direction 0
CP-95 Output B Polarity 0
Table 3-37 Entering Output B Control Parameters
CP Parameter Name Parameter Value
CP-93 Output B Segment Enter “1” to activate Output B during the constant pitch
plateau segment of the Follower profile.
Enter “2” to activate Output B during the constant pitch
plateau and Accel/Decel segment of the Follower profile.
Enter “3” to activate Output B during the Dwell
segment of the Follower profile.
CP-94 Output B Direction Enter “1” to activate Output B during the forward
direction.
Enter “2” to activate Output B during the reverse
direction.
Enter “3” to activate Output B during the forward and
reverse directions.
CP-95 Output B Polarity Enter “0” to activate Output B as Active Low Voltage
Level.
Enter “1” to activate Output B as Active High Voltage
Level.