Vue de la page 31
2 - 17
Figure 2-20 Forward Limit
Figure 2-21 Reverse Limit
Forward
Limit
12
13
J4
13
14
J4
Reverse
Limit
Forward Limit (J4 pins 12,13)
When Forward Limit is closed (edge-
triggered), it prevents the follower
from moving forward. When the
M–Traverse detects a Forward Limit,
it will go to F–Stop from Forward Jog,
Home Seek or Run, if CP-37 is set to
“1”. If CP-37 is set to “2”, then the
M-Traverse will begin a reverse
profile when it detects a Forward
Limit. To deactivate Forward limit,
use any reverse command (e.g.,
Reverse Jog).
Reverse Limit (J4 pins 13,14)
When Reverse Limit is closed (edge-
triggered), it prevents the follower
from moving in reverse. When the
M–Traverse detects a Reverse Limit,
it will go to F–Stop from either Run,
Reverse Jog or Home Seek (any
reverse move). To deactivate
Reverse limit, use any forward
command (e.g., Forward Jog).