4 - 9
Output Test #8 - To Test the Discrete Outputs
To enter this test, press the “Status” key to increment (or the “Tach” key
to decrement) until the number “8” is visible on the right side of the
upper LED display.
Only the “Help” diagnostic indicator and the number “8” will be visible
on the upper LED display during this test. To run this test, connect the
outputs to a pull up resistor and either a meter or LED, or connect the
outputs to a relay and either lights or sound.
Press “Enter” to start the test.
Press keys 1 - 7 to activate the outputs.
Press To Activate
1 Drive Enable
2 Batch Done
3 Alarm
4 Profile Dir.
5 At-Home
6 Output A
7 Output B
Press “Clear” to exit the test.
Press “Code Select” only if you want to exit diagnostics.
Speed Command Out Test #9- To Test the Speed Command Out
To enter this test, press the “Status” key to increment (or the “Tach” key
to decrement) until the number “9” is visible on the right side of the
upper LED display.
Use an oscilloscope to view Speed Command Analog Output (J1 Pin 9).
The output should ramp from +10 volts to –10 volts, then back to +10
volts.
Press “Enter” to start the test.
Press “Clear” to exit the test.
Press “Code Select” only if you want to exit diagnostics.