MV-53 DISCRETE INPUTS - GROUP A
The Discrete Inputs - Group A displays the status of the Jog, Jog Forward/Reverse, Run, Wait,
F-Stop, and Keypad Lockout discrete inputs. The number “1” indicates an open, or logic high
level. The number “0” indicates a closed, or logic low level (shorted to common). In the example
below, “Jog Forward/Reverse” is the open or logic high level.
Jog
Jog Forward/Reverse
Run
Wait
F-Stop
Keypad Lockout
MV-54 DISCRETE INPUTS - GROUP B
The Discrete Inputs - Group B displays the status of the Forward Limit, Reverse limit, Home
Sync, Setpoint Select A and Setpoint Select B discrete inputs. The number “1” indicates an open,
or logic high level. The number “0” indicates a closed, or logic low level (shorted to common). In
the example below, “Reverse Limit” is the open or logic high level.
Forward Limit
Reverse Limit
Not Used
Home Sync
Setpoint Select A
Setpoint Select B