3 - 56
OUTPUT MONITORING
These MVs monitor the M–Traverse's outputs.
MV-47 DAC OUTPUT
The DAC Output displays the present level of the analog speed command output to the
motor drive. The DAC output displays in DAC bits. A value of 4095 indicates a 100%
positive output and a value of -4095 indicates a 100% negative output.
MV-48 TRIM OUTPUT
The Trim Output is the calculated output of the compensation algorithm (gain plus
integral). This value is displays in DAC bits. A value of 4095 indicates a 100% positive
output and a value of -4095 indicates a 100% negative output.
MV-56 DISCRETE OUTPUTS - GROUP A
The Discrete Output - Group A displays the status of the Drive Enable, Batch Done,
Alarm, Profile Direction, At-Home and Output A discrete outputs. The number “1”
indicates an inactive or de-energized (logic high) level. The number “0” indicates an
active or energized (logic low) level. In the example below, “Batch Done” is the inactive
or de-energized (logic high) level.
Drive Enable
Batch Done
Alarm
Profile Direction
At-Home
Output A