3 - 36
Table 3-26 Entering Follower Scaling Analog Setpoint Parameters
CP Parameter Name Parameter Value
CP-84 Analog Input Allocation
CP-21 Follower Engineering Units
CP-34 Max RPM Feedback
CP-31 PPR Feedback
CP-33 Max RPM Lead
CP-30 PPR Lead
Setting CP-84 to a value of "6" or "7"
allocates the analog input to be used
as the Follower Setpoint 1 or Follower
Setpoint 2, respectively.
Enter the Follower Engineering Unit
value for an analog setpoint level of
10.0 volts with a lead of Max RPM
Lead (CP-33) and feedback of Max
RPM Feedback (CP-34).
Enter the maximum operating RPMs
measured at the feedback sensor shaft.
Enter the resolution of the feedback
sensor.
Enter the maximum operating RPMs
measured at the lead sensor shaft.
Enter the resolution of the lead
sensor.