3 - 29
Table 3-20 Entering Follower Scaling Analog Lead Parameters
CP Parameter Name Parameter Value
CP-84 Analog Input Allocation
CP-21 Follower Engineering Units
CP-34 Max RPM Feedback
CP-31 PPR Feedback
Setting CP-84 to a value of "1"
allocates the analog input to be used
as the lead signal.
Enter the Follower Engineering Unit
value for an analog lead level of
10.0 volts and feedback of Max RPM
Feedback (CP-34). This is typically a
value of 1.000.
Enter the maximum operating RPMs
measured at the feedback sensor shaft.
Enter the resolution of the follower
feedback sensor.
Note: The Max RPM Lead (CP-33) and PPR Lead (CP-30) control parameters, used
for scaling Follower mode with a frequency lead, are ignored when using
analog lead scaling.