Contrex ML-TRIM Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 180
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
1 - 5
Figure 1-2 is an example of the Follower mode of operation in a pump application. The
scaling format allows the operator to enter the setpoint as a ratio of ingredient B to
ingredient A. The ML–Trim compares the setpoint ratio to the Follower sensor shaft
feedback and Lead sensor shaft feedback to calculate any speed error. When the
ML–Trim finds speed error, the control algorithm adjusts the Speed Command Out to
the motor drive and reduces the error to zero.
Figure 1-2 ML–Trim Follower Mode
Motor Drive ML–Trim
Speed
Command
Out
Lead Motor
Sensor
Pump
Feedback Frequency
Motor Drive ML–Trim
Speed
Command
Out
Follower Motor
Sensor
Pump
Feedback Frequency
Ingredient B
Ingredient A
Follower
Lead
Final Product
Lead Frequency
Contrex
CODE
SELECT
SET
POINT
TACH
7
8 9
4 5 6
1
2 3
0
.
ENTER
CLEAR
ontrex
C
ontrex
C
Contrex
CODE
SELECT
SET
POINT
TACH
7
8 9
4 5 6
1
2 3
0
.
ENTER
CLEAR
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 179 180

Commentaires sur ces manuels

Pas de commentaire